By modality · Vascular ultrasound reporting software
Vascular ultrasound reporting software for vascular labs, with FDA clearance and what federal buyers paid
The short answer
Vascular ultrasound reporting software is the system a vascular lab uses to capture velocities and diameters from the ultrasound machine, fill a structured worksheet for each vessel, and produce the signed report that goes to the referring surgeon or cardiologist. The systems buyers actually see are Digisonics, Merge Cardio and SCImage. They file under different parts of the FDA rulebook, and federal award records show real prices: $62,889 for a single-site vascular imaging system, $228,800 for a vascular ultrasound reporting system at a VA medical center, and $274,230.64 for an echo and vascular reporting system. Radiological.ai does not replace a vascular lab system; it is the assistant layer that triages and drafts on the radiology side of the same workflow.
A vascular lab report is mostly numbers. Peak systolic velocity at each carotid segment, the ICA to CCA ratio, a diameter and a stenosis category, a graft surveillance velocity, a vein reflux time in seconds. The sonographer takes those measurements on the machine, the interpreting physician checks them, and the report has to carry them to the chart as discrete values rather than a paragraph someone retyped.
Page one for this search is vendors describing their own product, so this page does something else. It lists what a vascular reporting system has to do, which part of the FDA classification each one sits in, and what real buyers paid, using federal contract records you can look up by award ID. Radiological.ai is not a vascular lab system and does not pretend to be one. If your physicians also read general radiology studies, we work upstream of the report, triaging the worklist and drafting the findings.
Worklist
Structured report
DraftRun the assistant to draft this report for review.
Decision support. The radiologist reviews and signs every study.
Decision support for qualified clinicians. Radiological.ai does not provide a diagnosis and is not a substitute for professional judgment.
Flag · prioritize · draft · you review and sign
Decision support not a diagnosis
You review & sign
If the physicians reading your vascular studies also read general ultrasound, our page on AI ultrasound reporting covers the dictated radiology workflow, and OB ultrasound reporting software shows the same primary-source comparison for the obstetric side. For what the category costs before you request quotes, see ultrasound reporting software pricing.
Vascular reporting is usually one line in a larger imaging budget. Radiology software pricing benchmarks the neighboring categories against the same federal award data, structured radiology reporting covers the template and discrete-field design that worksheets depend on, and radiology software contract negotiation covers the interface and renewal terms that decide what year two costs. The regulation behind product code LLZ is public at 21 CFR 892.2050.
Primary source
What United States federal buyers paid for vascular ultrasound reporting systems
Every award below names a vascular reporting or vascular imaging system in its own contract description. These are signed Department of Veterans Affairs awards, not list prices, and each award ID can be looked up directly in USAspending.
| Federal award ID | Buyer and date | What the award record says it bought | Obligated amount |
|---|---|---|---|
| VA255P1414 | Veterans Affairs, Sep 2009 | Echo vascular reporting system (SCImage) | $274,230.64 |
| VA25715P2991 | Veterans Affairs, Sep 2015 | Vascular ultrasound reporting system (Digisonics) | $228,800.00 |
| 36C25718C0025 | Veterans Affairs, Nov 2017 | DigiView service contract (Digisonics), ongoing support on an installed system | $203,265.00 |
| VA25814C0065 | Veterans Affairs, Jul 2014 | Vascular imaging system for one VA health care system (Digisonics) | $62,889.00 |
Source: USAspending.gov prime award search for the phrases vascular ultrasound reporting, vascular reporting and Digisonics, run on November 16, 2026. Only four awards describe a vascular reporting or imaging system outright; other Digisonics awards in the same search were small support purchases and are left out. The spread from $62,889 to $274,230.64 is mostly scope: one lab versus a multi-site rollout with echo reporting bundled in. On the regulatory side, Merge Cardio holds K192276, cleared September 20, 2019 under product code LLZ, a radiological image processing system at 21 CFR 892.2050, and Digisonics holds K970402 under the same code. As with other reporting tools, a record keeping product does not need a clearance of its own, so a missing 510(k) says little. Check the K number only when a vendor claims the software interprets or characterizes a finding.
Why it works
What your group gets with vascular ultrasound reporting software
The worksheet is the product, so test it on your own protocols
A vascular lab does not run one protocol. Carotid duplex, lower extremity arterial with ankle brachial indices, venous reflux, dialysis access, aortic and mesenteric studies each have a different worksheet, different measurement points and different stenosis criteria. Ask each vendor to build your three most common protocols in front of you, with your velocity thresholds, and watch what happens when a sonographer skips a vessel or enters a value outside a plausible range. The systems differ less in the number of templates they ship than in how quickly a lab manager can change one when the medical director revises a criterion. If that edit needs a vendor ticket, price the delay.
Measurements must arrive by DICOM structured report, or someone retypes them
The reason to buy a reporting system rather than use a word processor is that velocities and diameters come off the machine without being typed. That works through DICOM structured reporting from each ultrasound platform, and it is where installs stall, because the older machines in the lab are the ones that export poorly. Get the machine models and software versions you run written into the quote, and ask for a reference lab with the same models. Then ask the other half of the question: how does the signed report leave. A PDF into the EMR is acceptable for the referring office, but you also want discrete values over HL7 or FHIR if your quality program counts stenosis grades or reflux rates across a year.
Accreditation reviews the report, so the report has to be consistent
Most vascular labs are accredited, and the accrediting body reviews sample reports for the required elements and for agreement between the measurements and the stated conclusion. A system that forces the same fields and the same terminology every time does more for that review than any dashboard. Ask whether the stenosis category is calculated from the entered velocities by rules you control, or typed by the reader, because the second approach is where the mismatches appear. Ask also whether an amended report keeps the original, with who changed what and when. Neither question shows up on a feature grid and both come up in the first audit.
What it handles
Flagged, prioritized and drafted for your review
The assistant pre-reads each study, surfaces a region of interest for review, re-prioritizes the worklist, and drafts the structured report in your template. You confirm, edit and sign.
- Triages the radiology worklist so suspected time-critical studies surface first
- Flags suspected findings on cross-sectional and plain film studies for the radiologist to review
- Drafts the structured radiology report into your own template
- Hands a consistently coded report to whichever system files it
- Connects over standard DICOM and HL7 alongside your PACS and vascular lab system
- The radiologist reviews every flag and signs every report
Region of interest flagged for review
A focal region is surfaced on the sample study for the radiologist to review. The assistant does not characterize it as a diagnosis.
Suspected finding flagged for radiologist review. Correlate clinically and confirm. Draft for review and sign-off.
Why Radiological.ai
One assistant across the whole read
Not three vendors stitched together. Flag, prioritize and draft in one calm pane, on X-ray, CT and MRI, with the radiologist signing every study.
Flags suspected findings
A second set of eyes surfaces regions of interest for review on every study, so a suspected finding is less likely to slip past late in a shift.
Prioritizes the worklist
Suspected-critical studies move to the top, so urgent reads surface ahead of routine follow-ups across your sites and shifts.
Drafts the report
A structured draft arrives in your template, ready to edit and sign. The draft saves the typing and the measuring, never the judgment.
Good questions
Questions about vascular ultrasound reporting software
Explore more
More ways teams read with Radiological.ai
AI chest X-ray
A second set of flags on high-volume chest films, drafted and ready.
Learn moreAI CT scan analysis
Triage and draft on CT, where minutes matter most.
Learn moreAI MRI analysis
Support across long MRI reads and the reports they generate.
Learn moreFrom the blog: best AI radiology software in 2026, how much radiology AI costs, how to implement AI in a radiology workflow, and AI radiology companies.
Read more studies, with the assistant alongside you
Flag suspected findings, prioritize the worklist, and draft the structured report. You review and sign every study.
Radiological.ai is a workflow and decision-support tool for qualified clinicians. It does not provide a diagnosis and is not a substitute for professional medical judgment.